      LC-MS is a technique that integrates liquid chromatography with mass spectrometry to achieve qualitative and quantitative analysis of complex samples. In LC-MS, MS1 and MS2 detections correspond to the first- and second-stage mass spectrometry analysis, respectively. Below is an overview of the process for performing MS1 and MS2 detection in LC-MS:

       

      Liquid Chromatography Separation

      LC-MS begins with liquid chromatography separation, where components in the sample are separated using a stationary phase, mobile phase, and gradient elution conditions.

       

      Ionization

      After liquid chromatography separation, the sample solution is introduced into the ionization source of the mass spectrometer, where the sample molecules are converted into charged ions. Common ionization methods used in bioanalysis include Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI).

       

      MS1 Detection (First-Stage Mass Spectrometry)

      The charged ions enter the mass spectrometer and undergo first-stage mass spectrometry (MS1) analysis. During MS1, a mass analyzer (e.g., quadrupole, time-of-flight, or orbital trap) separates the ions based on their mass-to-charge ratio (m/z). The mass spectrometer records the signal intensity of the ions to generate the MS1 spectrum, which depicts the m/z values and corresponding signal intensities for the sample components.

       

      MS2 Detection (Second-Stage Mass Spectrometry)

      In some experiments, MS2 analysis is necessary to obtain more detailed structural insights. In MS2, a specific precursor ion selected from MS1 undergoes fragmentation, typically through Collision-Induced Dissociation (CID) or more advanced dissociation techniques such as Electron Transfer Dissociation (ETD) or Electron Capture Dissociation (ECD). The fragment ions (product ions) are then analyzed by a second mass analyzer (in some mass spectrometers, such as Q-TOF or orbital trap, the same mass analyzer can be used for both precursor and fragment ion analysis).

       

      Generation of the MS2 Spectrum

      The mass spectrometer records the signal intensity of the fragment ions to generate the MS2 spectrum. This spectrum shows the m/z values of the fragment ions produced from precursor ion fragmentation and their corresponding signal intensities. By analyzing the MS2 spectrum, structural information about the target molecule, such as amino acid sequences and modification sites, can be obtained.

       

      In LC-MS analysis, different mass spectrometry modes can be chosen based on experimental needs, such as Full Scan, Selected Ion Monitoring (SIM), Multiple Reaction Monitoring (MRM), or Data-dependent Acquisition (DDA).

       

      Full Scan Mode records the MS1 spectrum across the entire m/z range, capturing information on all ions in the sample.

       

      SIM Mode selects specific ions of certain m/z ratios for detection, improving sensitivity and quantitative accuracy.

       

      MRM Mode detects specific precursor ion-product ion transitions and is widely used for quantitative analysis.

       

      DDA Mode automatically selects precursor ions for MS2 analysis based on ion intensity in the MS1 spectrum, commonly applied in proteomics and peptide identification.

       

      MS1 and MS2 detections in LC-MS correspond to first- and second-stage mass spectrometry analysis, respectively. MS1 detection provides basic information on the m/z and signal intensity of the sample components, offering essential data for structural identification and quantitative analysis. MS2 detection provides detailed structural information about the target molecule by fragmenting selected precursor ions and analyzing the resulting product ions.

       

      Different mass spectrometry modes can be selected to obtain the required information based on experimental needs. Whether Full Scan, SIM, MRM, or DDA modes are employed, LC-MS technology provides comprehensive qualitative and quantitative data to support biomedical research, drug discovery, environmental analysis, and other fields.

       